CFVMD - FC-87 FLUORINERT BRAND ELECTRONIC LIQUID

Product Identification

Product ID:FC-87 FLUORINERT BRAND ELECTRONIC LIQUID
MSDS Date:07/09/1997
FSC:6850
NIIN:00F054441
MSDS Number: CFVMD

Responsible Party
MINNESOTA MINING/SPECIALTY CHEMICALS DIV
3M CTR
ST PAUL, MN 55144-1000
US

Emergency Phone: 612-733-1110

Info Phone: 612-733-1110

Cage: 28112

Contractor
MINNESOTA MINING AND MFG CO PERFOMANCE CHEM AND FLUIDS DIV
SAINT PAUL, MN 55144-1000 US

Telephone: 800-364-3577/651-737-6501

Cage: 28112

Ingredients

PERFLUORO COMPOUNDS, C5-18

CAS: 86508-42-1

Fraction By Weight: 100%

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:VEHICLES CAN ALTER SKIN ABSORPTION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:VEHICLES CAN ALTER SKIN ABSORPTION.

First Aid

First Aid:EYES: FLUSH W/LARGE AMOUNTS OF WATER. SKIN: WASH W/SOAP &
WATER. INHALATION: REMOVE TO FRESH AIR. OBTAIN MEDICAL ATTENTION IN
ALL CASES.

Fire Fighting

Flash Point Method:SCC
Flash Point:NONE
Lower Limits:NONFLAMMABLE
Upper Limits:NONFLAMMABLE
Extinguishing Media:NONFLAMMABLE.
Fire Fighting Procedures:WEAR FULL PROTECTIVE CLOTHING/HELMET/POSITIVE
PRESSURE SCBA/BUNKER COAT/PANTS/BANDS AROUND ARMS/WAIST/LEGS/FACE
MASK & PROTECTIVE COVERING FOR HEAD AREA. (SUPP)
Unusual Fire/Explosion Hazard:EXPOSURE TO EXTREME HEAT CAN GIVE RISE TO
THERMAL DECOMPOSITION. KEEP CONTAINERS COOL W/WATER SPRAY WHEN
EXPOSED TO FIRE TO AVOID RUPTURE.

Accidental Release

Spill Release Procedures:LARGE: PROVIDE EXHAUST VENTILATION/IN CONFINED
SPACES. COLLECT MATERIAL W/AN ABSORBENT. PLACE IN AN APPROVED
CONTAINER.

Handling

Handling and Storage Precautions:STORE UNDER NORMAL WAREHOUSE
CONDITIONS. FOR INDUSTRIAL USE ONLY. NOT INTENDED FOR USE AS A
MEDICAL DEVICE/DRUG.
Other Precautions:SMOKING CAN RESULT IN CONTAMINATION OF THE TOBACCO
&/SMOKE & LEAD TO THE FORMATION OF THE HAZARDOUS DECOMPOSITION
PRODUCTS. AVOID BREATHING OF THERMAL DECOMPOSITION PRODUCTS.

Exposure Controls

Respiratory Protection:USE HALF-MASK SUPPLIED AIR RESPIRATOR/FULL FACE
SUPPLIED AIR RESPIRATOR.
Ventilation:LOCAL EXHAUST: SUFFICIENT TO MAINTAIN LEVELS BELOW EXPOSURE
LIMITS.
Protective Gloves:NOT REQUIRED
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS
Work Hygienic Practices:AS GOOD INDUSTRIAL HYGIENE PRACTICE.
Supplemental Safety and Health
SPECIAL FIRE PROCEDURES CONT'D: AVOID BREATHING THE PRODUCTS &
SUBSTANCES THAT MAY RESULT FROM THE THERMAL DECOMPOSITION OF THE
PRODUCT/THE OTHER SUBSTANCES IN THE FIRE ZONES.

Chemical Properties

Boiling Pt:B.P. Text:78.8-96.8F
Vapor Pres:610
Vapor Density:10
Spec Gravity:1.6
Evaporation Rate & Reference:(BUO AC = 1): >1
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS ODORLESS LIQUID
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ACTIVE METALS, ALKALI & ALKALINE EARTH METALS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:HYDROGEN FLUORIDE &
PERFLUOROISOBUTYLENE.

Disposal

Waste Disposal Methods:DISPOSE/INCINERATE IN AN INDUSTRIAL/COMMERCIAL
FACILITY CAPABLE OF HANDLING HALOGENATED WASTE IAW/FEDERAL, STATE &
LOCAL REGULATIONS. RECLAIM IF FEASIBLE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this